Machine Safety

can_t_find_the_right_part_banner1

Livingston & Haven supplies Machine Safety from the brands you trust. As an official distributor of Electrical Products, Livingston & Haven is able to offer full product support, catalogs, and custom items.

If you have any questions or don't see the product you are looking for, feel free to call, use our chat feature or contact us here. Our experts know everything there is to know about these parts and can help you find the Electrical Products you need.

Per page:  

Item #: 753005304
Part # 2981062
Model Code: PSR-SPP- 24UC/ESL4/3X1/1X2/B

quantity

Item #: 753005257
Part # 2981143
Model Code: PSR-SCP- 24DC/ESD/5X1/1X2/ T 1

quantity

Item #: 753000245
Part # 2981428
Model Code: PSR-SCP- 24DC/ESD/5X1/1X2/300

quantity

Item #: 753000246
Part # 2981431
Model Code: PSR-SPP- 24DC/ESD/5X1/1X2/300

quantity

Item #: 900115010
Model Code: PSR-SCP- 24DC/SDC4/2X1/B
Industrial Ethernet Switch
Safety relay for emergency stop, safety door, and magnetic switches, as well as light grid, up to SIL 3 or Cat 4, PL e according to EN ISO 13849, 2 N/O contacts, TBUS interface, automatic or manual activation, plug-in screw connection terminal blocks.
  • Up to Cat 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • Single and two-channel control
  • 2 enabling current paths, 1 signaling current path
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Modular system with TBUS extension
quantity

Item #: 753036947
Model Code: PSR-SPP- 24DC/SDC4/2X1/B
Industrial Ethernet Switch
Safety relay for emergency stop, safety door, and magnetic switches, as well as light grid, up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, 2 N/O contacts, TBUS interface, automatic or manual activation, plug-in spring-cage connection terminal blocks.
  • Up to Cat 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • Single and two-channel control
  • 2 enabling current paths, 1 signaling current path
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Modular system with TBUS extension
quantity

Item #: 900103293
Model Code: PSR-SCP- 24DC/ESD/4X1/30
Lightning/Surge Arrester
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts dropout delayed from 0.1 s to 30 s, plug-in screw connection terminal blocks.
  • Maximum of 3 undelayed and 2 dropout delay contacts
  • Manually monitored and automatic activation
  • Up to Cat 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Protective labels to prevent manipulation of the set time or electronic protection against manipulation
  • Single and two-channel control|Adjustable delay time of 0.2 s to 300 s
quantity

Item #: 753036380
Model Code: PSR-SPP- 24DC/ESD/4X1/30
Inline Terminal
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts dropout delayed from 0.1 s to 30 s, plug-in spring-cage connection terminal blocks.
  • Maximum of 3 undelayed and 2 dropout delay contacts
  • Manually monitored and automatic activation
  • Up to Cat 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Protective labels to prevent manipulation of the set time or electronic protection against manipulation
  • Single and two-channel control|Adjustable delay time of 0.2 s to 300 s
quantity

Item #: 753036383
Model Code: PSR-SCP- 24DC/SIM4
Lightning/Surge Arrester
Interface module, for up to four safety sensors/switches with N/O or N/C contact, screw connection.
  • 4 Two-channel N/O or N/C contact inputs
  • Up to Cat 3/PL d according to ISO 13849-1, SILCL 2 according to IEC 62061, SIL 2 according to IEC 61508
  • 4 PLC diagnostic outputs for evaluating the switching state of the safety sensors
  • 4 LEDs as status indicators for the relevant sensor/switch
  • PSR-TBUS connection
quantity

Item #: 457719758

Part #: BNS04U4
Model Code: BNS 813-D04-R12-100-20-01

quantity